Part Number Hot Search : 
TA7348P DJ110 UBA2021 IRGB4056 RKV501KJ P9105 DG447 HCM12
Product Description
Full Text Search
 

To Download ADIS16362PCBZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Six Degrees of Freedom Inertial Sensor ADIS16362
FEATURES
Triaxis digital gyroscope with digital range scaling 75/sec, 150/sec, 300/sec settings Tight orthogonal alignment: <0.05 Triaxis digital accelerometer: 1.7 g Autonomous operation and data collection No external configuration commands required Start-up time: 180 ms Sleep mode recovery time: 4 ms Factory-calibrated sensitivity, bias, and axial alignment Calibration temperature range: -20C to +70C SPI-compatible serial interface Embedded temperature sensor Programmable operation and control Automatic and manual bias correction controls Bartlett window FIR filter length, number of taps Digital I/O: data ready, alarm indicator, general-purpose Alarms for condition monitoring Sleep mode for power management DAC output voltage Enable external sample clock input: up to 1.2 kHz Single-command self-test Single-supply operation: 4.75 V to 5.25 V 2000 g shock survivability Operating temperature range: -40C to +105C
FUNCTIONAL BLOCK DIAGRAM
AUX_ ADC TEMPERATURE SENSOR TRIAXIS MEMS ANGULAR RATE SENSOR CS SIGNAL CONDITIONING AND CONVERSION CALIBRATION AND DIGITAL PROCESSING OUTPUT REGISTERS AND SPI INTERFACE SCLK DIN DOUT AUX_ DAC
TRIAXIS MEMS ACCELERATION SENSOR ALARMS DIGITAL CONTROL POWER MANAGEMENT VCC
SELF-TEST
GND
ADIS16362
RST DIO1 DIO2 DIO3 DIO4/ CLKIN
08179-001
Figure 1.
APPLICATIONS
Medical instrumentation Robotics Platform control Navigation
GENERAL DESCRIPTION
The ADIS16362 iSensor(R) is a complete inertial system that includes a triaxis gyroscope and triaxis accelerometer. Each sensor in the ADIS16362 combines industry-leading iMEMS(R) technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyro bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measurements over a temperature range of -20C to +70C. The ADIS16362 provides a simple, cost-effective method for integrating accurate, multiaxis, inertial sensing into industrial systems, especially when compared with the complexity and investment associated with discrete designs. All necessary
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners.
motion testing and calibration are part of the production process at the factory, greatly reducing system integration time. Tight orthogonal alignment simplifies inertial frame alignment in navigation systems. An improved SPI interface and register structure provide faster data collection and configuration control. The ADIS16362 uses a compatible pinout and the same package as the ADIS1635x family. Therefore, systems that currently use the ADIS1635x family can upgrade their performance with minor firmware adjustments in their processor designs. This compact module is approximately 23 mm x 23 mm x 23 mm and provides a flexible connector interface that enables multiple mounting orientation options.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 (c)2009 Analog Devices, Inc. All rights reserved.
ADIS16362 TABLE OF CONTENTS
Features .............................................................................................. 1 Applications ....................................................................................... 1 Functional Block Diagram .............................................................. 1 General Description ......................................................................... 1 Revision History ............................................................................... 2 Specifications..................................................................................... 3 Timing Specifications .................................................................. 5 Timing Diagrams.......................................................................... 5 Absolute Maximum Ratings............................................................ 6 ESD Caution .................................................................................. 6 Pin Configuration and Function Descriptions ............................. 7 Typical Performance Characteristics ............................................. 8 Theory of Operation ........................................................................ 9 Basic Operation ............................................................................ 9 Reading Sensor Data .................................................................... 9 Device Configuration .................................................................. 9 Memory Map .............................................................................. 10 Burst Read Data Collection ...................................................... 11 Output Data Registers ............................................................... 11 Calibration................................................................................... 12 Operational Control................................................................... 12 Input/Output Functions ............................................................ 14 Diagnostics .................................................................................. 15 Product Identification................................................................ 16 Applications Information .............................................................. 17 Installation/Handling................................................................. 17 Gyroscope Bias Optimization ................................................... 17 Input ADC Channel ................................................................... 17 Interface Printed Circuit Board (PCB) .................................... 17 Outline Dimensions ....................................................................... 18 Ordering Guide .......................................................................... 18
REVISION HISTORY
8/09--Revision 0: Initial Version
Rev. 0 | Page 2 of 20
ADIS16362 SPECIFICATIONS
TA = 25C, VCC = 5.0 V, angular rate = 0/sec, dynamic range = 300/sec 1 g, unless otherwise noted. Table 1.
Parameter GYROSCOPES Dynamic Range Initial Sensitivity Test Conditions/Comments Min 300 0.0495 Typ 350 0.05 0.025 0.0125 50 0.05 0.5 0.1 3 0.007 2.0 0.01 0.05 0.3 0.8 0.044 330 14.5 1400 Max Unit /sec /sec/LSB /sec/LSB /sec/LSB ppm/C Degrees Degrees % of FS /sec /sec /hr /sec/C /sec/g /sec/V /sec rms /sec/Hz rms Hz kHz LSB g mg/LSB ppm/C Degrees Degrees % of FS mg g m/sec/hr mg/C mg/V mg rms mg/Hz rms Hz kHz LSB C/LSB Bits LSB LSB LSB LSB V pF
Sensitivity Temperature Coefficient Misalignment Nonlinearity Initial Bias Error In-Run Bias Stability Angular Random Walk Bias Temperature Coefficient Linear Acceleration Effect on Bias Bias Voltage Sensitivity Output Noise Rate Noise Density 3 dB Bandwidth Sensor Resonant Frequency Self-Test Change in Output Response ACCELEROMETERS Dynamic Range Initial Sensitivity Sensitivity Temperature Coefficient Misalignment Nonlinearity Initial Bias Error In-Run Bias Stability Velocity Random Walk Bias Temperature Coefficient Bias Voltage Sensitivity Output Noise Noise Density 3 dB Bandwidth Sensor Resonant Frequency Self-Test Change in Output Response TEMPERATURE SENSOR Scale Factor ADC INPUT Resolution Integral Nonlinearity Differential Nonlinearity Offset Error Gain Error Input Range Input Capacitance
Dynamic range = 300/sec Dynamic range = 150/sec Dynamic range = 75/sec -20C TA +70C Reference to z-axis accelerometer Axis-to-frame (package) Best fit straight line 1 1 , SMPL_PRD = 0x0001 1 , SMPL_PRD = 0x0001 -20C TA +70C Any axis, 1 (MSC_CTRL[7] = 1) VCC = 4.75 V to 5.25 V 300/sec range, no filtering f = 25 Hz, 300/sec range, no filtering
0.0505
300/sec range setting Each axis
696 1.7 0.330
2449
-20C TA +70C Axis-to-axis, = 90 ideal Axis-to-frame (package) Best fit straight line 1 1 1 -20C TA +70C VCC = 4.75 V to 5.25 V No filtering No filtering
0.333 40 0.2 0.5 0.1 6 41 0.09 0.05 2.5 5 0.23 330 5.5
0.336
X-axis and y-axis Output = 0x0000 at 25C (5C)
505 0.136 12 2 1 4 2 0
1671
3.3 20
During acquisition
Rev. 0 | Page 3 of 20
ADIS16362
Parameter DAC OUTPUT Resolution Relative Accuracy Differential Nonlinearity Offset Error Gain Error Output Range Output Impedance Output Settling Time LOGIC INPUTS 1 Input High Voltage, VIH Input Low Voltage, VIL CS Wake-Up Pulse Width Logic 1 Input Current, IIH Logic 0 Input Current, IIL All Pins Except RST RST Pin Input Capacitance, CIN DIGITAL OUTPUTS1 Output High Voltage, VOH Output Low Voltage, VOL FLASH MEMORY Data Retention 3 FUNCTIONAL TIMES 4 Power-On Start-Up Time Reset Recovery Time Sleep Mode Recovery Time Flash Memory Test Time Automatic Self-Test Time CONVERSION RATE Clock Accuracy Sync Input Clock POWER SUPPLY Power Supply Current Test Conditions/Comments 5 k/100 pF to GND 101 LSB input code 4095 LSB Min Typ 12 4 1 5 0.5 0 2 10 2.0 CS signal to wake up from sleep mode 20 VIH = 3.3 V VIL = 0 V 0.2 40 1 10 ISOURCE = 1.6 mA ISINK = 1.6 mA Endurance 2 TJ = 85C Time until data is available Normal mode, SMPL_PRD 0x09 Low power mode, SMPL_PRD 0x0A Normal mode, SMPL_PRD 0x09 Low power mode, SMPL_PRD 0x0A Normal mode, SMPL_PRD 0x09 Low power mode, SMPL_PRD 0x0A Normal mode, SMPL_PRD 0x09 Low power mode, SMPL_PRD 0x0A SMPL_PRD = 0x01 SMPL_PRD = 0x01 to 0xFF 2.4 0.4 10,000 20 180 250 60 130 4 9 17 90 12 0.413 0.8 5 4.75 819.2 3 1.2 5.25 10 60 0.8 0.55 3.3 Max Unit Bits LSB LSB mV % V s V V V s A A mA pF V V Cycles Years ms ms ms ms ms ms ms ms ms SPS % kHz V mA mA A
Operating voltage range, VCC Low power mode Normal mode Sleep mode
5.0 24 49 500
1 2
The digital I/O signals are driven by an internal 3.3 V supply, and the inputs are 5 V tolerant. Endurance is qualified as per JEDEC Standard 22, Method A117, and measured at -40C, +25C, +85C, and +125C. 3 The data retention lifetime equivalent is at a junction temperature (TJ) of 85C as per JEDEC Standard 22, Method A117. Data retention lifetime decreases with junction temperature. 4 These times do not include thermal settling and internal filter response times (330 Hz bandwidth), which may affect overall accuracy. 5 The sync input clock functions below the specified minimum value, at reduced performance levels.
Rev. 0 | Page 4 of 20
ADIS16362
TIMING SPECIFICATIONS
TA = 25C, VCC = 5 V, unless otherwise noted. Table 2.
Normal Mode (SMPL_PRD 0x09) Min 1 Typ Max 0.01 2.0 9 40 48.8 100 24.4 48.8 5 12.5 5 12.5 5 5 100 600 833 Low Power Mode (SMPL_PRD 0x0A) Min1 Typ Max 0.01 0.3 75 100 48.8 100 24.4 48.8 5 12.5 5 12.5 5 Burst Read Min1 Typ Max 0.01 1.0 1/fSCLK 48.8 100 24.4 48.8 5 5 5 5 100 600 833 12.5 12.5
Parameter fSCLK tSTALL tREADRATE tCS tDAV tDSU tDHD tSCLKR, tSCLKF tDR, tDF tSFS t1 tx t2 t3
1
Description Serial clock Stall period between data Read rate Chip select to clock edge DOUT valid after SCLK edge DIN setup time before SCLK rising edge DIN hold time after SCLK rising edge SCLK rise/fall times DOUT rise/fall times CS high after SCLK edge Input sync positive pulse width Input sync low time Input sync to data ready output Input sync period
Unit MHz s s ns ns ns ns ns ns ns s s s s
Guaranteed by design and characterization, but not tested in production.
TIMING DIAGRAMS
CS
tCS
SCLK 1 2 3 4 5 6 15 16
tSFS
tDAV
DOUT MSB DB14 DB13 DB12 DB11 DB10 DB2 DB1 LSB
tDSU
DIN R/W A6 A5
tDHD
A4 A3 A2 D2 D1 LSB
08179-002
Figure 2. SPI Timing and Sequence
tREADRATE tSTALL
CS
08179-003
SCLK
Figure 3. Stall Time and Data Rate
t3 t2 t1
SYNC CLOCK (DIO4) DATA READY
08179-004
tX
Figure 4. Input Clock Timing Diagram
Rev. 0 | Page 5 of 20
ADIS16362 ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Acceleration Any Axis, Unpowered Any Axis, Powered VCC to GND Digital Input Voltage to GND Digital Output Voltage to GND Analog Input to GND Operating Temperature Range Storage Temperature Range
1
Rating 2000 g 2000 g -0.3 V to +6.0 V -0.3 V to +5.3 V -0.3 V to VCC + 0.3 V -0.3 V to +3.6 V -40C to +105C -65C to +125C1, 2
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 4. Package Characteristics
Package Type 24-Lead Module JA 39.8C/W JC 14.2C/W Device Weight 16 grams
Extended exposure to temperatures outside the specified temperature range of -40C to +105C can adversely affect the accuracy of the factory calibration. For best accuracy, store the parts within the specified operating range of -40C to +105C. 2 Although the device is capable of withstanding short-term exposure to 150C, long-term exposure threatens internal mechanical integrity.
ESD CAUTION
Rev. 0 | Page 6 of 20
ADIS16362 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
ADIS16362
AUX_ADC
TOP VIEW (Not to Scale)
SCLK DIO3 DIO1 DIO2 GND GND DNC DNC VCC DIN
1
3
5
7
9
11
13
15
17
19
21
23
2
DIO4/CLKIN
4
DOUT
6
CS
8
RST
10
VCC
12
VCC
14
GND
16
DNC
18
DNC
20
AUX_DAC
22
DNC
24
DNC
Figure 5. Pin Configuration
Z-AXIS
aZ gZ
Y-AXIS X-AXIS
aY aX gY gX
PIN 23 PIN 1 ORIGIN ALIGNMENT REFERENCE POINT SEE MSC_CTRL[6].
Figure 6. Axial Orientation
Table 5. Pin Function Descriptions
Pin No. 1 2 3 4 5 6 7, 9 8 10, 11, 12 13, 14, 15 16, 17, 18, 19, 22, 23, 24 20 21
1
Mnemonic DIO3 DIO4/CLKIN SCLK DOUT DIN CS DIO1, DIO2 RST VCC GND DNC AUX_DAC AUX_ADC
Type 1 I/O I/O I O I I I/O I S S N/A O I
Description Configurable Digital Input/Output. Configurable Digital Input/Output or Sync Clock Input. SPI Serial Clock. SPI Data Output. Clocks output on SCLK falling edge. SPI Data Input. Clocks input on SCLK rising edge. SPI Chip Select. Configurable Digital Input/Output. Reset. Power Supply. Power Ground. Do Not Connect. Auxiliary, 12-Bit DAC Output. Auxiliary, 12-Bit ADC Input.
I/O is input/output, I is input, O is output, S is supply, N/A is not applicable. Rev. 0 | Page 7 of 20
08179-006
NOTES 1. ACCELERATION (aX, aY, aZ) AND ROTATIONAL (gX, gY, gZ) ARROWS INDICATE THE DIRECTION OF MOTION THAT PRODUCES A POSITIVE OUTPUT.
08179-005
NOTES 1. THIS REPRESENTATION DISPLAYS THE TOP VIEW PINOUT FOR THE MATING SOCKET CONNECTOR. 2. THE ACTUAL CONNECTOR PINS ARE NOT VISIBLE FROM THE TOP VIEW. 3. MATING CONNECTOR: SAMTEC CLM-112-02 OR EQUIVALENT. 4. DNC = DO NOT CONNECT.
DNC
ADIS16362 TYPICAL PERFORMANCE CHARACTERISTICS
0.1 0.001
ROOT ALLAN VARIANCE (/sec)
+1 0.01 MEAN
ROOT ALLAN VARIANCE (g)
0.0001 +1 MEAN -1
-1
08179-007
1
10
100
1k
10k
1
10
100
1k
10k
Tau (Seconds)
Tau (Seconds)
Figure 7. Gyroscope Allan Variance
Figure 8. Accelerometer Allan Variance
Rev. 0 | Page 8 of 20
08179-008
0.001 0.1
0.00001 0.1
ADIS16362 THEORY OF OPERATION
BASIC OPERATION
The ADIS16362 is an autonomous sensor system that starts up after it has a valid power supply voltage and begins producing inertial measurement data at the factory default sample rate setting of 819.2 SPS. After each sample cycle, the sensor data is loaded into the output registers, and DIO1 pulses high, which provides a new data ready control signal for driving systemlevel interrupt service routines. In a typical system, a master processor accesses the output data registers through the SPI interface, using the connection diagram shown in Figure 9. Table 6 provides a generic functional description for each pin on the master processor. Table 7 describes the typical master processor settings that are normally found in a configuration register and used for communicating with the ADIS16362.
VDD I/O LINES ARE COMPATIBLE WITH 3.3V OR 5V LOGIC LEVELS
10
The user registers provide addressing for all input/output operations on the SPI interface. Each 16-bit register has two 7-bit addresses: one for its upper byte and one for its lower byte. Table 8 lists the lower byte address for each register, and Figure 10 shows the generic bit assignments.
08179-010
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
UPPER BYTE
LOWER BYTE
Figure 10. Generic Register Bit Assignments
READING SENSOR DATA
Although the ADIS16362 produces data independently, it operates as a SPI slave device that communicates with system (master) processors using the 16-bit segments displayed in Figure 11. Individual register reads require two of these 16-bit sequences. The first 16-bit sequence provides the read command bit (R/W = 0) and the target register address (A6 to A0). The second sequence transmits the register contents (D15 to D0) on the DOUT line. For example, if DIN = 0x0A00, the contents of XACCL_OUT are shifted out on the DOUT line during the next 16-bit sequence. The SPI operates in full-duplex mode, which means that the master processor can read the output data from DOUT while using the same SCLK pulses to transmit the next target address on DIN.
5V
11
12
SYSTEM PROCESSOR SPI MASTER
SS SCLK MOSI MISO IRQ
6 3 5 4 7
CS SCLK DIN DOUT DIO1
13
ADIS16362
SPI SLAVE
14
15
08179-009
DEVICE CONFIGURATION
The user register memory map (see Table 8) identifies configuration registers with either a W or R/W. Configuration commands also use the bit sequence shown in Figure 11. If the MSB = 1, the last eight bits (DC7 to DC0) in the DIN sequence are loaded into the memory address associated with the address bits (A6 to A0). For example, if DIN = 0xA11F, 0x1F is loaded into Address 0x21 (XACCL_OFF, upper byte) at the conclusion of the data frame. The master processor initiates the backup function by setting GLOB_CMD[3] = 1 (DIN = 0xBE04). This command copies the user registers into their assigned flash memory locations and requires the power supply to stay within its normal operating range for the entire 50 ms process. The FLASH_CNT register provides a running count of these events for monitoring the long-term reliability of the flash memory.
Figure 9. Electrical Connection Diagram
Table 6. Generic Master Processor Pin Names and Functions
Pin Name SS IRQ MOSI MISO SCLK Function Slave select Interrupt request Master output, slave input Master input, slave output Serial clock
Table 7. Generic Master Processor SPI Settings
Processor Setting Master SCLK Rate 2 MHz1 SPI Mode 3 MSB First Mode 16-Bit Mode
1
Description The ADIS16362 operates as a slave Normal mode, SMPL_PRD[7:0] 0x09 CPOL = 1 (polarity), CHPA = 1 (phase) Bit sequence Shift register/data length
For burst read, SCLK rate 1 MHz. For low power mode, SCLK rate 300 kHz.
CS SCLK DIN DOUT R/W D15 A6 D14 A5 D13 A4 D12 A3 D11 A2 D10 A1 D9 A0 D8 DC7 D7 DC6 D6 DC5 D5 DC4 D4 DC3 D3 DC2 D2 DC1 D1 DC0 D0 R/W D15 A6 D14 A5 D13
08179-011
NOTES 1. DOUT BITS ARE BASED ON THE PREVIOUS 16-BIT SEQUENCE (R = 0).
Figure 11. SPI Communication Bit Sequence
Rev. 0 | Page 9 of 20
ADIS16362
MEMORY MAP
Table 8. User Register Memory Map
Name FLASH_CNT SUPPLY_OUT XGYRO_OUT YGYRO_OUT ZGYRO_OUT XACCL_OUT YACCL_OUT ZACCL_OUT XTEMP_OUT YTEMP_OUT ZTEMP_OUT AUX_ADC Reserved XGYRO_OFF YGYRO_OFF ZGYRO_OFF XACCL_OFF YACCL_OFF ZACCL_OFF ALM_MAG1 ALM_MAG2 ALM_SMPL1 ALM_SMPL2 ALM_CTRL AUX_DAC GPIO_CTRL MSC_CTRL SMPL_PRD SENS_AVG SLP_CNT DIAG_STAT GLOB_CMD Reserved LOT_ID1 LOT_ID2 SERIAL_NUM PROD_ID
1
R/W R R R R R R R R R R R R N/A R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W W R W N/A R R R R
Flash Backup Yes No No No No No No No No No No No N/A Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes Yes Yes No No N/A N/A Yes Yes Yes Yes
Address 1 0x00 0x02 0x04 0x06 0x08 0x0A 0x0C 0x0E 0x10 0x12 0x14 0x16 0x18 0x1A 0x1C 0x1E 0x20 0x22 0x24 0x26 0x28 0x2A 0x2C 0x2E 0x30 0x32 0x34 0x36 0x38 0x3A 0x3C 0x3E 0x40 to 0x51 0x52 0x54 0x56 0x58
Default N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0006 0x0001 0x0402 0x0000 0x0000 0x0000 N/A N/A N/A N/A 0x3F86
Register Description Flash memory write count Power supply measurement X-axis gyroscope output Y-axis gyroscope output Z-axis gyroscope output X-axis accelerometer output Y-axis accelerometer output Z-axis accelerometer output X-axis gyroscope temperature measurement Y-axis gyroscope temperature measurement Z-axis gyroscope temperature measurement Auxiliary ADC output Reserved X-axis gyroscope bias offset factor Y-axis gyroscope bias offset factor Z-axis gyroscope bias offset factor X-axis acceleration bias offset factor Y-axis acceleration bias offset factor Z-axis acceleration bias offset factor Alarm 1 amplitude threshold Alarm 2 amplitude threshold Alarm 1 sample size Alarm 2 sample size Alarm control Auxiliary DAC data Auxiliary digital input/output control Miscellaneous control: data ready, self-test Internal sample period (rate) control Dynamic range and digital filter control Sleep mode control System status System command Reserved Lot Identification Code 1 Lot Identification Code 2 Serial number Product identification
Bit Function N/A See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 See Table 9 N/A See Table 15 See Table 15 See Table 15 See Table 16 See Table 16 See Table 16 See Table 27 See Table 27 See Table 28 See Table 28 See Table 29 See Table 23 See Table 21 See Table 22 See Table 18 See Table 20 See Table 19 See Table 26 See Table 17 N/A See Table 32 See Table 32 See Table 32 See Table 32
Each register contains two bytes. The address of the lower byte is displayed. The address of the upper byte is equal to the address of the lower byte plus 1.
Rev. 0 | Page 10 of 20
ADIS16362
BURST READ DATA COLLECTION
Burst read data collection is a process-efficient method for collecting data from the ADIS16362. In burst read, all output registers are clocked out on DOUT, 16 bits at a time, in sequential data cycles (each separated by one SCLK period). To start a burst read sequence, set DIN = 0x3E00. The contents of each output register are then shifted out on DOUT, starting with SUPPLY_OUT and ending with AUX_ADC (see Figure 13). The addressing sequence shown in Table 8 determines the order of the outputs in burst read. Table 11. Rotation Rate, Twos Complement Format
Rotation Rate +300/sec +0.1/sec +0.05/sec 0/sec -0.05/sec -0.1/sec -300/sec Decimal +6000 LSB +2 LSB +1 LSB 0 LSB -1 LSB -2 LSB -6000 LSB Hex 0x1770 0x0002 0x0001 0x0000 0x3FFF 0x3FFE 0x2890 Binary XX01 0111 0111 0000 XX00 0000 0000 0010 XX00 0000 0000 0001 XX00 0000 0000 0000 XX11 1111 1111 1111 XX11 1111 1111 1110 XX10 1000 1001 0000
OUTPUT DATA REGISTERS
Each output data register uses the format in Figure 12 and Table 9. Figure 6 shows the positive direction for each inertial sensor. The ND bit is equal to 1 when the register contains unread data. The EA bit is high when any error/alarm flag in the DIAG_STAT register is equal to 1.
MSB FOR 14-BIT OUTPUT
08179-013
Table 12. Acceleration, Twos Complement Format
Acceleration +1.7 g +0.667 mg +0.333 mg 0g -0.333 mg -0.667 mg -1.7 g Decimal +5105 LSB +2 LSB +1 LSB 0 LSB -1 LSB -2 LSB -5105 LSB Hex 0x13F1 0x0002 0x0001 0x0000 0x3FFF 0x3FFE 0x2C0F Binary XX01 0011 1111 0001 XX00 0000 0000 0010 XX00 0000 0000 0001 XX00 0000 0000 0000 XX11 1111 1111 1111 XX11 1111 1111 1110 XX10 1100 0000 1111
ND EA MSB FOR 12-BIT OUTPUT
Figure 12. Output Register Bit Assignments
Table 9. Output Data Register Formats
Register SUPPLY_OUT XGYRO_OUT1 YGYRO_OUT1 ZGYRO_OUT1 XACCL_OUT YACCL_OUT ZACCL_OUT XTEMP_OUT2 YTEMP_OUT2 ZTEMP_OUT2 AUX_ADC
1 2
Bits 12 14 14 14 14 14 14 12 12 12 12
Scale 2.418 mV 0.05/sec 0.05/sec 0.05/sec 0.333 mg 0.333 mg 0.333 mg 0.136C 0.136C 0.136C 805.8 V
Reference See Table 10 See Table 11 See Table 11 See Table 11 See Table 12 See Table 12 See Table 12 See Table 13 See Table 13 See Table 13 See Table 14
Table 13. Temperature, Twos Complement Format
Temperature +105C +85C +25.272C +25.136C +25C +24.864C +24.728C -40C Decimal +588 LSB +441 LSB +2 LSB +1 LSB 0 LSB -1 LSB -2 LSB -478 LSB Hex 0x24C 0x1B9 0x002 0x001 0x000 0xFFF 0xFFE 0xE22 Binary XXXX 0010 0100 1100 XXXX 0001 1011 1001 XXXX 0000 0000 0010 XXXX 0000 0000 0001 XXXX 0000 0000 0000 XXXX 1111 1111 1111 XXXX 1111 1111 1110 XXXX 1110 0010 0010
Table 14. Analog Input, Offset Binary Format
Input Voltage 3.3 V 1V 1.6116 mV 805.8 V 0V Decimal 4095 LSB 1241 LSB 2 LSB 1 LSB 0 LSB Hex 0xFFF 0x4D9 0x002 0x001 0x000 Binary XXXX 1111 1111 1111 XXXX 0100 1101 1001 XXXX 0000 0000 0010 XXXX 0000 0000 0001 XXXX 0000 0000 0000
Assumes that the scaling is set to 300/sec. This factor scales with the range. 0x0000 = 25C (5C).
Table 10. Power Supply, Offset Binary Format
Supply Voltage 5.25 V 5.002418 V 5V 4.997582 V 4.75 V Decimal 2171 LSB 2069 LSB 2068 LSB 2067 LSB 1964 LSB
CS
Hex 0x87B 0x815 0x814 0x813 0x7AC
1
Binary XXXX 1000 0111 1011 XXXX 1000 0001 0101 XXXX 1000 0001 0100 XXXX 1000 0001 0011 XXXX 0111 1010 1100
2 3
4
5
12
SCLK
DIN
0x3E00
DON'T CARE
DOUT
PREVIOUS
SUPPLY_OUT
XGYRO_OUT
YGYRO_OUT
ZGYRO_OUT
AUX_ADC
08179-012
NOTES 1. THE DOUT LINE HAS BEEN SIMPLIFIED FOR SPACE CONSTRAINTS BUT, IDEALLY, SHOULD INCLUDE ALL REGISTERS FROM SUPPLY_OUT THROUGH AUX_ADC.
Figure 13. Burst Read Sequence
Rev. 0 | Page 11 of 20
ADIS16362
CALIBRATION
Manual Bias Calibration
The bias offset registers in Table 15 and Table 16 provide a manual adjustment function for the output of each sensor. For example, if XGYRO_OFF = 0x1FF6 (DIN = 0x9B1F, 0x9AF6), the XGYRO_OUT offset shifts by -10 LSBs, or -0.125/sec. Table 15. XGYRO_OFF, YGYRO_OFF, ZGYRO_OFF Bit Descriptions
Bit [15:13] [12:0] Description (Default = 0x0000) Not used. Data bits. Twos complement, 0.0125/sec per LSB. Typical adjustment range = 50/sec.
Restoring Factory Calibration
Set GLOB_CMD[1] = 1 (DIN = 0xBE02) to execute the factory calibration restore function. This function resets each user calibration register to 0x0000 (see Table 15 and Table 16), resets all sensor data to 0, and automatically updates the flash memory within 50 ms (see Table 17).
Linear Acceleration Bias Compensation (Gyroscope)
Set MSC_CTRL[7] = 1 (DIN = 0xB486) to enable correction for low frequency acceleration influences on gyroscope bias. Note that the DIN sequence also preserves the factory default condition for the data ready function (see Table 22).
OPERATIONAL CONTROL
Global Commands
The GLOB_CMD register provides trigger bits for several useful functions. Setting the assigned bit to 1 starts each operation, which returns the bit to 0 after completion. For example, set GLOB_CMD[7] = 1 (DIN = 0xBE80) to execute a software reset, which stops the sensor operation and runs the device through its start-up sequence. This sequence includes loading the control registers with their respective flash memory locations prior to producing new data. Reading the GLOB_CMD register (DIN = 0x3E00) starts the burst read sequence. Table 17. GLOB_CMD Bit Descriptions
Bit [15:8] [7] [6:5] [4] [3] [2] [1] [0] Description Not used Software reset command Not used Precision autonull command Flash update command Auxiliary DAC data latch Factory calibration restore command Autonull command
Table 16. XACCL_OFF, YACCL_OFF, ZACCL_OFF Bit Descriptions
Bit [15:12] [11:0] Description (Default = 0x0000) Not used. Data bits. Twos complement, 0.333 mg/LSB. Typical adjustment range = 0.3 g.
Gyroscope Automatic Bias Null Calibration
Set GLOB_CMD[0] = 1 (DIN = 0xBE01) to execute the automatic bias null calibration function. This function measures all three gyroscope output registers and then loads each gyroscope offset register with the opposite value to provide a quick bias calibration. All sensor data is then reset to 0, and the flash memory is updated automatically within 50 ms (see Table 17).
Gyroscope Precision Automatic Bias Null Calibration
Set GLOB_CMD[4] = 1 (DIN = 0xBE10) to execute the precision automatic bias null calibration function. This function takes the sensor offline for 30 sec while it collects a set of data and calculates more accurate bias correction factors for each gyroscope. After this function is executed, the newly calculated correction factor is loaded into the gyroscope offset registers, all sensor data is reset to 0, and the flash memory is updated automatically within 50 ms (see Table 17).
Rev. 0 | Page 12 of 20
ADIS16362
Internal Sample Rate
The SMPL_PRD register provides discrete sample rate settings using the bit assignments in Table 18 and the following equation: tS = tB x (NS + 1) For example, when SMPL_PRD[7:0] = 0x0A, the sample rate is 149 SPS. Table 18. SMPL_PRD Bit Descriptions
Bit [15:8] [7] [6:0] Description (Default = 0x0001) Not used Time base (tB) 0 = 0.61035 ms, 1 = 18.921 ms Increment setting (NS) Internal sample period = tS = tB x (NS + 1)
Digital Filtering
A programmable low-pass filter can provide additional noise reduction on the inertial sensor outputs. This filter contains two cascaded averaging filters that provide a Bartlett window, FIR filter response (see Figure 14). For example, set SENS_AVG[2:0] = 100 (DIN = 0xB804) to set each stage to 16 taps. When used with the default sample rate of 819.2 SPS, this value reduces the sensor bandwidth to approximately 16 Hz.
0 -20 -40
MAGNITUDE (dB)
-60 -80 -100 -120 -140 0.001 N=2 N=4 N = 16 N = 64
08179-015
The default sample rate setting of 819.2 SPS preserves the sensor bandwidth and provides optimal performance. For systems that value slower sample rates, keep the internal sample rate at 819.2 SPS. Use the programmable filter (SENS_AVG) to reduce the bandwidth, which helps to prevent aliasing. The data ready function (MSC_CTRL) can drive an interrupt routine that uses a counter to help ensure data coherence at the reduced rates.
0.01
0.1
1
FREQUENCY (Ratio)
Power Management
Setting SMPL_PRD 0x0A also sets the sensor to low power mode. For systems that require lower power dissipation, insystem characterization helps users to quantify the associated performance trade-offs. In addition to sensor performance, this mode affects SPI data rates (see Table 2). Set SLP_CNT[8] = 1 (DIN = 0xBB01) to start the indefinite sleep mode, which requires a CS assertion (high to low), reset, or power cycle to wake up. Use SLP_CNT[7:0] to put the device into sleep mode for a specified period. For example, SLP_CNT[7:0] = 0x64 (DIN = 0xBA64) puts the ADIS16362 to sleep for 50 sec. Table 19. SLP_CNT Bit Descriptions
Bit [15:9] [8] [7:0] Description Not used Indefinite sleep mode; set to 1 Programmable sleep time bits, 0.5 sec/LSB
Figure 14. Bartlett Window, FIR Filter Frequency Response (Phase Delay = N Samples)
Dynamic Range
The SENS_AVG[10:8] bits provide three dynamic range settings for this gyroscope. The lower dynamic range settings (75/sec and 150/sec) limit the minimum filter tap sizes to maintain resolution. For example, set SENS_AVG[10:8] = 010 (DIN = 0xB902) for a measurement range of 150/sec. Because this setting can influence the filter settings, program SENS_AVG[10:8] and then SENS_AVG[2:0] if more filtering is required. Table 20. SENS_AVG Bit Descriptions
Bit [15:11] [10:8] Description Not used Measurement range (sensitivity) selection 100 = 300/sec (default condition) 010 = 150/sec, filter taps 4 (Bits[2:0] 0x02) 001 = 75/sec, filter taps 16 (Bits[2:0] 0x04) Not used Number of taps in each stage, N = 2M
[7:3] [2:0]
Rev. 0 | Page 13 of 20
ADIS16362
INPUT/OUTPUT FUNCTIONS
General-Purpose I/O
DIO1, DIO2, DIO3, and DIO4 are configurable, general-purpose I/O lines that serve multiple purposes according to the following control register priority: MSC_CTRL, ALM_CTRL, and GPIO_CTRL. For example, set GPIO_CTRL = 0x080C (DIN = 0xB308, and then 0xB20C) to configure DIO1 and DIO2 as inputs and DIO3 and DIO4 as outputs, with DIO3 set low and DIO4 set high. In this configuration, read GPIO_CTRL (DIN = 0x3200).The digital state of DIO1 and DIO2 is in GPIO_CTRL[9:8]. Table 21. GPIO_CTRL Bit Descriptions
Bit [15:12] [11] [10] [9] [8] [7:4] [3] [2] [1] [0] Description Not used General-Purpose I/O Line 4 (DIO4) data level General-Purpose I/O Line 3 (DIO3) data level General-Purpose I/O Line 2 (DIO2) data level General-Purpose I/O Line 1 (DIO1) data level Not used General-Purpose I/O Line 4 (DIO4) direction control (1 = output, 0 = input) General-Purpose I/O Line 3 (DIO3) direction control (1 = output, 0 = input) General-Purpose I/O Line 2 (DIO2) direction control (1 = output, 0 = input) General-Purpose I/O Line 1 (DIO1) direction control (1 = output, 0 = input)
Table 22. MSC_CTRL Bit Descriptions
Bit [15:12] [11] [10] [9] [8] [7] [6] [5:3] [2] [1] [0] Description Not used Memory test (cleared upon completion) (1 = enabled, 0 = disabled) Internal self-test enable (cleared upon completion) (1 = enabled, 0 = disabled) Manual self-test, negative stimulus (1 = enabled, 0 = disabled) Manual self-test, positive stimulus (1 = enabled, 0 = disabled) Linear acceleration bias compensation for gyroscopes (1 = enabled, 0 = disabled) Linear accelerometer origin alignment (1 = enabled, 0 = disabled) Not used Data ready enable (1 = enabled, 0 = disabled) Data ready polarity (1 = active high, 0 = active low) Data ready line select (1 = DIO2, 0 = DIO1)
Auxiliary DAC
The 12-bit AUX_DAC line can drive its output to within 5 mV of the ground reference when it is not sinking current. As the output approaches 0 V, the linearity begins to degrade (~100 LSB beginning point). As the sink current increases, the nonlinear range increases. The DAC latch command moves the values of the AUX_DAC register into the DAC input register, enabling both bytes to take effect at the same time. Table 23. AUX_DAC Bit Descriptions
Bit [15:12] [11:0] Description Not used Data bits, scale factor = 0.8059 mV/LSB Offset binary format, 0 V = 0 LSB
Input Clock Configuration
The input clock function allows for external control oversampling in the ADIS16362. Set GPIO_CTRL[3] = 0 (DIN = 0x0B200) and SMPL_PRD[7:0] = 0x00 (DIN = 0xB600) to enable this function. See Table 2 and Figure 4 for timing information.
Data Ready I/O Indicator
The factory default sets DIO1 as a positive data ready indicator signal. The MSC_CTRL[2:0] bits provide configuration options for changing the default. For example, set MSC_CTRL[2:0] = 100 (DIN = 0xB404) to change the polarity of the data ready signal on DIO1 for interrupt inputs that require negative logic inputs for activation. The pulse width is between 100 s and 200 s over all conditions.
DIN 0xB0D9 0xB104 0xBE04
Table 24. Setting AUX_DAC = 1 V
Description AUX_DAC[7:0] = 0xD9 (217 LSB). AUX_DAC[15:8] = 0x04 (1024 LSB). GLOB_CMD[2] = 1. Move values into the DAC input register, resulting in a 1 V output level.
Rev. 0 | Page 14 of 20
ADIS16362
DIAGNOSTICS
Self-Test
The self-test function allows the user to verify the mechanical integrity of each MEMS sensor. It applies an electrostatic force to each sensor element, which results in mechanical displacement that simulates a response to actual motion. Table 1 lists the expected response for each sensor, which provides pass/fail criteria. Set MSC_CTRL[10] = 1 (DIN = 0xB504) to run the internal self-test routine, which exercises all inertial sensors, measures each response, makes pass/fail decisions, and reports them to error flags in the DIAG_STAT register. MSC_CTRL[10] resets itself to 0 after completing the routine. The MSC_CTRL[9:8] bits provide manual control over the self-test function for investigation of potential failures. Table 25 outlines an example test flow for using this option to verify the x-axis gyroscope function. Table 25. Manual Self-Test Example Sequence
DIN 0xB601 0xB904 0xB802 0x0400 0xB502 0x0400 Description SMPL_PRD[7:0] = 0x01, sample rate = 819.2 SPS SENS_AVG[15:8] = 0x04, gyro range = 300/sec SENS_AVG[7:0] = 0x02, four-tap averaging filter Delay = 50 ms Read XGYRO_OUT MSC_CTRL[9] = 1, gyroscope negative self-test Delay = 50 ms Read XGYRO_OUT Determine whether the bias in the gyroscope output changes according to the expectation set in Table 1 MSC_CTRL[9:8] = 01, gyroscope/accelerometer positive self-test Delay = 50 ms Read XGYRO_OUT Determine whether the bias in the gyroscope changed according to the self-test response in Table 1 MSC_CTRL[15:8] = 0x00
Status
The error flags provide indicator functions for common system level issues. All of the flags are cleared (set to 0) after each DIAG_STAT register read cycle. If an error condition remains, the error flag returns to 1 during the next sample cycle. The DIAG_STAT[1:0] bits do not require a read of this register to return to 0. If the power supply voltage goes back into range, these two flags are cleared automatically. Table 26. DIAG_STAT Bit Descriptions
Bit [15] [14] [13] [12] [11] [10] [9] [8] [7] [6] [5] [4] [3] [2] [1] [0] Description Z-axis accelerometer self-test failure (1 = fail, 0 = pass) Y-axis accelerometer self-test failure (1 = fail, 0 = pass) X-axis accelerometer self-test failure (1 = fail, 0 = pass) Z-axis gyroscope self-test failure (1 = fail, 0 = pass) Y-axis gyroscope self-test failure (1 = fail, 0 = pass) X-axis gyroscope self-test failure (1 = fail, 0 = pass) Alarm 2 status (1 = active, 0 = inactive) Alarm 1 status (1 = active, 0 = inactive) Not used Flash test, checksum flag (1 = fail, 0 = pass) Self-test diagnostic error flag (1 = fail, 0 = pass) Sensor overrange (1 = fail, 0 = pass) SPI communication failure (1 = fail, 0 = pass) Flash update failure (1 = fail, 0 = pass) Power supply above 5.25 V (1 = power supply 5.25 V, 0 = power supply 5.25 V) Power supply below 4.75 V (1 = power supply 4.75 V, 0 = power supply 4.75 V)
0xB501
Alarm Registers
The alarm function provides monitoring for two independent conditions. The ALM_CTRL register provides control inputs for data source, data filtering (prior to comparison), static comparison, dynamic rate-of-change comparison, and output indicator configurations. The ALM_MAGx registers establish the trigger threshold and polarity configurations. Table 30 gives an example of how to configure a static alarm. The ALM_SMPLx registers provide the numbers of samples to use in the dynamic rate-of-change configuration. The period equals the number in the ALM_SMPLx register multiplied by the sample period time, which is established by the SMPL_PRD register. See Table 31 for an example of how to configure the sensor for this type of function.
0x0400
0xB500
Zero motion provides results that are more reliable. The settings in Table 25 are flexible and allow for optimization around speed and noise influence. For example, using fewer filtering taps decreases delay times but increases the possibility of noise influence.
Memory Test
Setting MSC_CTRL[11] = 1 (DIN = 0xB508) performs a checksum verification of the flash memory locations. The pass/fail result is loaded into DIAG_STAT[6].
Rev. 0 | Page 15 of 20
ADIS16362
Table 27. ALM_MAG1, ALM_MAG2 Bit Descriptions
Bit [15] [14] [13:0] Description Comparison polarity (1 = greater than, 0 = less than) Not used Data bits that match the format of the trigger source selection
Table 30. Alarm Configuration Example 1
DIN 0xAF55, 0xAE17 Description ALM_CTRL = 0x5517 Alarm 1 input = XACCL_OUT Alarm 2 input = XACCL_OUT Static level comparison, filtered data DIO2 output indicator, positive polarity ALM_MAG1 = 0x8341 Alarm 1 is true if XACCL_OUT > +0.5 g ALM_MAG2 = 0x3CBF. Alarm 2 is true if XACCL_OUT < -0.5 g
Table 28. ALM_SMPL1, ALM_SMPL2 Bit Descriptions
Bit [15:8] [7:0] Description Not used Data bits: number of samples (both 0x00 and 0x01 = 1)
0xA783, 0xA641 0xA93C, 0xA8BF
Table 31. Alarm Configuration Example 2
DIN 0xAF76, 0xAE87 Description ALM_CTRL = 0x7687 Alarm 1 input = YACCL_OUT Alarm 2 input = ZACCL_OUT Rate-of-change comparison, unfiltered data DIO2 output indicator, positive polarity SMPL_PRD = 0x0001 Sample rate = 819.2 SPS ALM_SMPL1 = 0x0008 Alarm 1 rate-of-change period = 9.77 ms ALM_SMPL2 = 0x0050 Alarm 2 rate-of-change period = 97.7 ms ALM_MAG1 = 0x8341 Alarm 1 is true if XACCL_OUT > +0.5 g ALM_MAG2 = 0x3CBE Alarm 2 is true if XACCL_OUT < -0.5 g
Table 29. ALM_CTRL Bit Descriptions
Bit [15:12] Description Alarm 2 source selection 0000 = disable 0001 = power supply output 0010 = x-axis gyroscope output 0011 = y-axis gyroscope output 0100 = z-axis gyroscope output 0101 = x-axis accelerometer output 0110 = y-axis accelerometer output 0111 = z-axis accelerometer output 1000 = x-axis gyroscope temperature output 1001 = y-axis gyroscope temperature output 1010 = z-axis gyroscope temperature output 1011 = auxiliary ADC input Alarm 1 source selection (same as Alarm 2) Rate-of-change (ROC) enable for Alarm 2 (1 = rate of change, 0 = static level) Rate-of-change (ROC) enable for Alarm 1 (1 = rate of change, 0 = static level) Not used Comparison data filter setting (1 = filtered data, 0 = unfiltered data) Not used Alarm output enable (1 = enabled, 0 = disabled) Alarm output polarity (1 = active high, 0 = active low) Alarm output line select (1 = DIO2, 0 = DIO1)
0xB601 0xAB08 0xAC50 0xA783, 0xA641 0xA93C, 0xA8BE
[11:8] [7] [6] [5] [4] [3] [2] [1] [0]
PRODUCT IDENTIFICATION
Table 32 provides a summary of the registers that identify the product: PROD_ID, which identifies the product type; LOT_ID1 and LOT_ID2, the 32-bit lot identification code; and SERIAL_NUM, which displays the 16-bit serial number. All four registers are two bytes in length. Table 32. Identification Registers
Register Name LOT_ID1 LOT_ID2 SERIAL_NUM PROD_ID Address 0x52 0x54 0x56 0x58 Description Lot Identification Code 1 Lot Identification Code 2 Serial number Product identification = 0x3F86 (hexadecimal number for 16,362)
Rev. 0 | Page 16 of 20
ADIS16362 APPLICATIONS INFORMATION
INSTALLATION/HANDLING
For ADIS16362 installation, use the following two-step process: 1. 2. Secure the baseplate using machine screws. Press the connector into its mate.
C1 VCC D R1 C2
08179-014
D
For removal, 1. 2. Gently pry the connector from its mate using a small slot screwdriver. Remove the screws and lift the part up.
Figure 15. Equivalent Analog Input Circuit (Conversion Phase: Switch Open, Track Phase: Switch Closed)
INTERFACE PRINTED CIRCUIT BOARD (PCB)
The ADIS16362/PCBZ includes one ADIS16362BLMZ and one interface PCB. The interface PCB simplifies the process of integrating the ADIS16362BMLZ into an existing processor system. J1 and J2 are dual-row, 2 mm (pitch) connectors that work with a number of ribbon cable systems, including 3M Part Number 152212-0100-GB (ribbon crimp connector) and 3M Part Number 3625/12 (ribbon cable). Figure 16 provides a hole pattern design for installing the ADIS16362BMLZ and the interface PCB onto the same surface. Figure 17 provides the pin assignments for each connector. The pin descriptions match those listed in Table 5. The ADIS16362 does not require external capacitors for normal operation, so the interface PCB does not use the C1/C2 pads (not shown in Figure 16).
23.75 21.24
Never attempt to unplug the connector by pulling on the plastic case or baseplate. Although the flexible connector is very reliable in normal operation, it can break when subjected to unreasonable handling. When broken, the flexible connector cannot be repaired. The AN-1041 Application Note provides more information about developing an appropriate mechanical interface design.
GYROSCOPE BIAS OPTIMIZATION
The factory calibration addresses initial bias errors along with temperature-dependent bias behaviors. Installation and certain environmental conditions can introduce modest bias errors. The precision autonull command (GLOB_CMD[4]) provides a simple predeployment method for correcting these errors to an accuracy of approximately 0.008/sec, using an average of 30 sec. Averaging the sensor output data for 100 sec can provide incremental performance gains, as well. Controlling device rotation, power supply, and temperature during these averaging times helps to ensure optimal accuracy during this process. Refer to the AN-1041 Application Note for more information about optimizing performance.
J2 1
2
INPUT ADC CHANNEL
The AUX_ADC register provides access to the auxiliary ADC input channel. The ADC is a 12-bit successive approximation converter that has an input circuit equivalent to the one shown in Figure 15. The maximum input is 3.3 V. The ESD protection diodes can handle 10 mA without causing irreversible damage. The on resistance (R1) of the switch has a typical value of 100 . The sampling capacitor, C2, has a typical value of 16 pF.
11
12
30.10
J1 1 2
27.70
1.20
11 12
08179-020
NOTES 1. DIMENSIONS IN MILLIMETERS.
Figure 16. Physical Diagram for the ADIS16362/PCBZ
J1 RST CS DNC GND GND VCC 1 3 5 7 9 11 2 4 6 8 10 12 SCLK DOUT DIN GND VCC VCC AUX_ADC AUX_DAC GND DNC DNC DIO2 1 3 5 7 9 11 J2 2 4 6 8 10 12 GND DIO3 DIO4 DNC DNC DIO1
08179-021
Figure 17. J1/J2 Pin Assignments
Rev. 0 | Page 17 of 20
ADIS16362 OUTLINE DIMENSIONS
31.900 31.700 31.500 23.454 23.200 22.946 2.382 BSC 9.464 9.210 8.956 (2x) 17.41 17.21 17.01 (2x) 4.20 4.00 3.80 (2x)
BOTTOM VIEW 21.410 21.210 21.010
1.588 BSC TOP VIEW 1.588 BSC 22.964 22.710 22.456
10.60 BSC
PIN 24
14.950 14.550 14.150 10.50 BSC FRONT VIEW
5.20 5.00 4.80 (2x)
1.00 BSC
7.18 BSC
CASTING FEATURE
PIN 1
0.05 BSC
12.10 BSC
2.00 BSC
23.504 23.250 22.996 2.660 2.500 2.340 SIDE VIEW DETAIL A 4.330 BSC DETAIL A 4.162 BSC
0.305 BSC (24x)
1.00 BSC (22x) 14.00 BSC
1.65 BSC
122208-C
Figure 18. 24-Lead Module with Connector Interface (ML-24-2) Dimensions shown in millimeters
ORDERING GUIDE
Model ADIS16362BMLZ 1 ADIS16362/PCBZ1
1
Temperature Range -40C to +105C
Package Description 24-Lead Module with Connector Interface Interface Board
Package Option ML-24-2
Z = RoHS Compliant Part.
Rev. 0 | Page 18 of 20
ADIS16362 NOTES
Rev. 0 | Page 19 of 20
ADIS16362 NOTES
(c)2009 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D08179-0-8/09(0)
Rev. 0 | Page 20 of 20


▲Up To Search▲   

 
Price & Availability of ADIS16362PCBZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .